Title 12 : Building, Utility, etc. Codes
Chapter 3 : Electrical Code

12-304 : Modifications.

Local modifications.

  1. Article 110.24(B) Available Fault Current. Modifications. Is locally amended by deleting it in its entirety with no replacement.
  2. Article 210.12(A). Arc-Fault Circuit-Interrupter Protection. Dwelling Units. Shall be locally amended by numbering the exception at the end as:
    "Exception 1" and adding the following after the exception:
    "Exception 2. Notwithstanding the above, Arc Fault Circuit Interrupters (AFCIs) shall be optional for bathrooms, laundry areas, garages, unfinished basements, which are portions or areas of the basement not intended as habitable rooms and limited to storage, work or similar area, and for branch circuits dedicated to supplying refrigeration equipment. Should there be any conflict within this section as to application, this exception shall prevail."
  3. Article 210.19(A)(3). Household Ranges and Cooking Appliances. Is amended locally by deleting in its entirety and replacing it with the following:
    "Section 210.19(A)(3) Household Ranges and Cooking Appliances. All range taps shall be on separate wired circuits."
  4. Article 210.52(A)(2). Wall Space. Shall be locally amended by adding the following at the end:
    "(4) Receptacles shall not be required in the wall space behind doors which may be opened fully against a wall surface. Wall space measurement shall begin at the edge of the door when fully opened."
  5. Article 210.52(C)(2). Island Countertop Spaces. Shall be locally amended by deleting in its entirety and replacing with:
    "(2) Island Countertop Spaces. The installation of receptacles for island counter spaces below the countertop shall be optional."
  6. Article 210.52(C)(3). Peninsular Countertop Spaces. Shall be locally amended by deleting in its entirety and replacing with:
    "(3) Peninsular Countertop Spaces. The installation of receptacles for peninsular counter spaces below the countertop shall be optional."
  7. Article 334.15(C). In Unfinished Basements and Crawlspaces. Shall be locally amended by adding the following at the end:
    "Exception: Non-metallic-Sheathed Cable shall not be required to be run through bored holes in unfinished basements and crawlspaces with less than four (4) feet and six (6) inches of clearance."
  8. Article 410.10. Luminaires in Specific Locations. Shall be locally amended by adding the following at the end:
    "(D) In Crawlspaces. Light fixtures in crawlspaces shall have guarded covers." (1999 Code, § 12-308)
Date Last Updated: 12/22/2025
Codification Date: 06/01/2024

Officials at Date of Last Codification:

Mayor - Andy White
Vice-Mayor - Fred Metz
Council Member - Sarah Herron
Council Member - Tommy Hunt
Council Member - Drew Miles
City Manager - Greg McClain
Assistant City Manager - Kevin Stoltenberg
City Recorder/Financial Services Director - Sherri Phillips
City Attorney - Melanie Davis