Legal Documents of Baneberry

Code of Baneberry

Baneberry
Title 12 : Building, Utility, etc. Codes
Chapter 1 : Codes Adopted

12-102 : Local modifications.

  1. The City of Baneberry (hereinafter referred to as the "City") WILL NOT adopt the following chapters: 19, 20, 21, 22, 23, 24, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44.
  2. The City WILL NOT adopt the following appendices: A, C, E, G, H, I, J, K, L, M, O, Q.
  3. When the International Residential One- and Two-Family Dwelling Code refers to the duties of certain officials named therein, that designated official in the City, who has duties corresponding to those of the named official in said "code" shall be deemed to be the responsible official insofar as enforcing the provisions of said "code" are concerned.
  4. The following provisions are added at the beginning of the code above

    Chapter 1: Administration:

    QUALITY CONTROL AND EVALUATION AND CERTIFICATION OF MATERIALS AND WORKMANSHIP IS NOT WITHIN THE PURVIEW OF THIS CODE EXCEPT AS SUCH RELATES TO THE PURPOSES DESCRIBED HEREIN.

    THE PERMITTING OR INSPECTION OF ANY BUILDING, PLAN, OR STRUCTURE DESCRIBED IN THIS CODE SHALL NOT BE CONSTRUED OR ACT AS A WARRANTEE OF THE PHYSICAL CONDITION OF ANY BUILDING OR STRUCTURE OR THE ADEQUACY OF ANY PLAN. NEITHER JEFFERSON COUNTY AND/OR ANY AGENT, EMPLOYEE OR REPRESENTATIVE OF JEFFERSON COUNTY SHALL BE LIABLE UNDER ANY THEORY FOR DAMAGES OF ANY KIND, RELATED TO ANY ALLEGED DEFECT, HAZARD, CONDITION, AND/ OR INADEQUACY OF ANY KIND OF SUCH BUILDING, STRUCTURE, OR PLAN AND SHALL NOT BE LIABLE FOR ANY ALLEGED FAILURE OF ANY COMPONENT OF SUCH CONSTRUCTION, BUILDING, STRUCTURE OR PLAN, WHICH MAY OCCUR AT ANY TIME, BEFORE, DURING, AND/OR AFTER ANY INSPECTION OR PERMITTING PERFORMED PURSUANT TO THIS CODE.

  5. Further, the following local amendments are hereby adopted:

    Section R101.1 Title

    Delete "[NAME OF JURISDICTION]" and replace with "City of Baneberry,

    Tennessee".

    Section R102.5 Appendices.

    "The following Appendices are specifically included in the adoption. All others are excluded."

    At the end of this section, insert the following:

    Appendix B: Sizing of Venting Systems Serving Appliances Equipped with Draft Hoods, Category I Appliances, and appliances Listed for Use with Type B Vents.

    Appendix C: Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems

    Appendix F: Radon Control Methods

    Appendix N: Venting Methods

    Appendix P: Sizing of Water Piping system

    Section 105.2 Work exempt from permit.

    Delete Item 1 in its entirety.

    Delete "2. Fences not over 7 feet (1829 mm) high," and insert "Fences" in its place.

    Table R301.2 (1) Climatic and Geographic Design Criteria.

    Insert "10PSF" in the Ground Snow Load.

    Insert "90" in the table for Wind Speed.

    Insert "NO" in the table for Topographic effects.

    Insert "C" in the table for Seismic Design Category.

    Insert "Severe" in the table for Weathering.

    Insert "12 inches" in the table for Frost Line Depth.

    Insert "Moderate to Heavy" in the table for Termite.

    Insert "19 degrees Fahrenheit" in the table for Winter Design Temp.

    Insert "NO" in the table for Ice Barrier Underlayment Required.

    Insert "210" in the table for Air Freezing Index.

    Insert "59.4" in the table for Mean Annual Temp.

    Flood hazard areas shall be as determined be the FEMA Maps.

    Section R301.2.2 Seismic provisions.

    Delete item 1, renumber item 2 to item 1 and insert "and townhouses" just after the word dwellings and at the end of the section, insert "All references to "townhouses in seismic design category C" in chapters 6, 7, and 28 shall not apply in Jefferson County."

    Section R302.S.1 Opening protection.

    Delete the words", equipped with a self-closing device" and insert a period after

    the word "door".

    Section R303.4 Mechanical ventilation.

    Add the word "(Optional)". In the section title after the word ventilation.

    Delete the words "the dwelling unit shall be provided with whole-house mechanical ventilation" and replace with the words "dwelling units provided

    with whole-house mechanical ventilation shall be".

    Section R312.2 Window Fall Protection.

    Delete section R312.2 and R312.2.1 in their entirety.

    Section R313 Automatic Fire Sprinkler System.

    Add the words "(Optional, see Tennessee Code Annotated, Section 68-120-101(a)(8) )." In the section title after the word "systems".

    Section R313.1 Townhouses automatic fire sprinkler systems.

    Delete the words "an automatic residential fire sprinkler system shall be installed in townhouses." And replace with "When an automatic residential fire sprinkler system is installed in townhouses, the following shall apply":

    Section R313.2 One- and two-family dwellings automatic fire sprinkler systems.

    Delete the words "an automatic residential fire sprinkler system shall be installed in one- and two-family dwellings." And replace with "When an automatic residential fire sprinkler system is installed in one- and two- family dwellings, the following shall apply":

    Section R502.11.4 Truss Design Drawings.

    Delete "to the building official and approve prior to installation" and replace it

    with "for review when required by the building official".

    Section R802.10.1 Truss Design Drawings.

    Delete "to the building official and approve prior to installation" and replace it

    with "for review when required by the building official".

    Table N1102.1.1 (R402.1.1) Insulation and Fenestration Requirements' By Component.

    In the row for climate zone "4 except Marine", Ceiling Value from "R49" to "R-38", and change the Wood Frame Wall R-Value from "20" or 13+5" to "13".

    Section N1102.2.6 (R402.2.6) Steel-Frame ceilings, walls, and floors.

    After the first occurrence of the word "of" insert "TableN1102.1.1 OR".

    Section N1102.4.1.1 (R102.4.1.1) Installation.

    Add the words" and visual inspection option." after the word "Installation" in the

    section title. Add the words ", and be field verified." after the word "construction".

    Section N1102.4.1.2 (R402.4.1.2) Testing.

    Add the word" (optional)" after the word "Testing" in the section title. Before the first sentence insert "Where required by the building official",

    Section N1103.1.1 (R403.1.1) Programmable thermostat.

    Add the word"(optional)". After the word "thermostat" in the section title.

    Before the first sentence insert "Where required by the building official.

    Section N1103.2.2 (R403.2.2) Sealing (Mandatory).

    Before the words "Duct" insert "Where required by the building official".

    Section N1103.6 (R403.6) Mechanical Ventilation (Mandatory).

    Delete the word "MANDATORY" and replace with word "Optional" in the section title.

    Delete "The building shall be provided with ventilation that meets" and replace

    with "Buildings provided with ventilation shall meet."

    Section N1103.9 (R403.9) Pools and in ground permanently installed spas (Mandatory).

    Delete the word "Mandatory" and replace with the word "Optional" in the section title. Before the first sentence insert "Where required by the building official".

    Section N1103.10 (R403.10) Pools and permanent spa energy consumption (Mandatory).

    Delete the word "Mandatory" and replace with the word "Optional" in the section title. Before the first sentence insert "Where required by the building official".

    Section P2603.S.1 Sewer depth.

    Delete "(NUMBER)" in two places and insert" twelve inches "in two places.

    Section AF103.S.3 Vent Pipe.

    At the end of the section insert "Exception: The vent pipe shall be allowed to terminate in the attic and may capped unless tests verify the radon potential to be 4 pCi/L or greater."

    Section AF103.12 Power Source.

    Delete Section AF103.12 in its entirety. (Ord. #220-06, April 2021)

Date Last Updated: 06/20/2022
Codification Date: 06/20/2022

Officials at Date of Last Codification:

Mayor - Donna Hernandez

Vice Mayor - Tom Carter

City Commissioner - Gary Zander